We can assume that a service for which a watchdog timeout was triggered
is unresponsive to a clean shutdown. However, it still makes sense to
execute the post-stop cleanup commands that can be configured with
ExecStopPost=. Hence, when the timeout is hit enter STOP_SIGKILL rather
than FINAL_SIGKILL.
offset = now(CLOCK_MONOTONIC) - s->watchdog_timestamp.monotonic;
if (offset >= s->watchdog_usec) {
log_error_unit(UNIT(s)->id, "%s watchdog timeout!", UNIT(s)->id);
offset = now(CLOCK_MONOTONIC) - s->watchdog_timestamp.monotonic;
if (offset >= s->watchdog_usec) {
log_error_unit(UNIT(s)->id, "%s watchdog timeout!", UNIT(s)->id);
- service_enter_signal(s, SERVICE_FINAL_SIGKILL, SERVICE_FAILURE_WATCHDOG);
+ service_enter_signal(s, SERVICE_STOP_SIGKILL, SERVICE_FAILURE_WATCHDOG);