X-Git-Url: https://www.chiark.greenend.org.uk/ucgi/~ianmdlvl/git?a=blobdiff_plain;f=man%2Fsystemd-nspawn.xml;h=a4f222c3495a6a14d17a6df538bc9074bf17e65b;hb=a049d1a9723b6608e45bf8f1a64dab5761dee555;hp=6518eb819e413979e2db86117e8606f61eb56c82;hpb=6afc95b73605833e6e966af1c466b5c08feb953f;p=elogind.git diff --git a/man/systemd-nspawn.xml b/man/systemd-nspawn.xml index 6518eb819..a4f222c34 100644 --- a/man/systemd-nspawn.xml +++ b/man/systemd-nspawn.xml @@ -21,7 +21,8 @@ along with systemd; If not, see . --> - + systemd-nspawn @@ -158,32 +159,6 @@ The following options are understood: - - - - - Prints a short help - text and exits. - - - - - - Prints a version string - and exits. - - - - - - - Turns off any status - output by the tool itself. When this - switch is used, the only output - from nspawn will be the console output - of the container OS itself. - - @@ -285,7 +260,7 @@ Assign the specified network interface to the - container. This will move the + container. This will remove the specified interface from the calling namespace and place it in the container. When the container @@ -299,12 +274,36 @@ container. + + + + Create a + macvlan interface + of the specified Ethernet network + interface and add it to the + container. A + macvlan interface + is a virtual interface that adds a + second MAC address to an existing + physical Ethernet link. The interface + in the container will be named after + the interface on the host, prefixed + with mv-. Note that + + implies + . This + option may be used more than once to + add multiple network interfaces to the + container. + + Create a virtual - Ethernet link between host and - container. The host side of the + Ethernet link + (veth) between host + and container. The host side of the Ethernet link will be available as a network interface named after the container's name (as specified with @@ -321,13 +320,17 @@ - Adds the host side of the - Ethernet link created with - - to the specified bridge. Note that - + Adds the host side of + the Ethernet link created with + to the + specified bridge. Note that + implies - . + . If + this option is used the host side of + the Ethernet link will use the + vb- prefix instead + of ve-. @@ -466,7 +469,7 @@ destination in the container. The option creates read-only bind - mount. + mounts. @@ -573,6 +576,20 @@ reported on the host. + + + + + + Turns off any status + output by the tool itself. When this + switch is used, the only output + from nspawn will be the console output + of the container OS itself. + + + +