#include "bus-errors.h"
#include "dbus.h"
#include "execute.h"
+#include "virt.h"
const UnitVTable * const unit_vtable[_UNIT_TYPE_MAX] = {
[UNIT_SERVICE] = &service_vtable,
pid_t control_pid,
bool main_pid_alien) {
- int sig, wait_for_exit = 0, r;
+ int sig, wait_for_exit = false, r;
assert(u);
assert(c);
log_warning_unit(u->id, "Failed to kill main process " PID_FMT " (%s): %s", main_pid, strna(comm), strerror(-r));
} else {
- wait_for_exit = !main_pid_alien;
+ if (!main_pid_alien)
+ wait_for_exit = true;
if (c->send_sighup)
kill(main_pid, SIGHUP);
if (r != -EAGAIN && r != -ESRCH && r != -ENOENT)
log_warning_unit(u->id, "Failed to kill control group: %s", strerror(-r));
} else if (r > 0) {
- wait_for_exit = true;
+
+ /* FIXME: Now, this is a terrible hack: in
+ * containers cgroup empty notifications don't
+ * work. Hence we'll not wait for them to run
+ * empty for now, since there is no way to
+ * detect when a service ends with no main PID
+ * known... */
+
+ if (detect_container(NULL) <= 0)
+ wait_for_exit = true;
if (c->send_sighup) {
set_free(pid_set);