along with systemd; If not, see <http://www.gnu.org/licenses/>.
***/
-#include <dbus/dbus.h>
-
#include <stdlib.h>
+#include "sd-bus.h"
#include "log.h"
-#include "dbus-common.h"
+#include "bus-util.h"
int main(int argc, char *argv[]) {
- DBusError error;
- DBusConnection *bus = NULL;
- DBusMessage *m = NULL;
- int r = EXIT_FAILURE;
-
- dbus_error_init(&error);
+ _cleanup_bus_flush_close_unref_ sd_bus *bus = NULL;
+ int r;
if (argc != 2) {
log_error("Incorrect number of arguments.");
- goto finish;
+ return EXIT_FAILURE;
}
+ elogind_set_program_name(argv[0]);
log_set_target(LOG_TARGET_AUTO);
log_parse_environment();
log_open();
+#if 0
/* We send this event to the private D-Bus socket and then the
* system instance will forward this to the system bus. We do
* this to avoid an activation loop when we start dbus when we
* are called when the dbus service is shut down. */
- bus = dbus_connection_open_private("unix:path=/run/systemd/private", &error);
- if (!bus) {
- log_warning("Failed to get D-Bus connection: %s", bus_error_message(&error));
- goto finish;
- }
-
- if (bus_check_peercred(bus) < 0) {
- log_error("Bus owner not root.");
- goto finish;
- }
-
- m = dbus_message_new_signal("/org/freedesktop/systemd1/agent", "org.freedesktop.systemd1.Agent", "Released");
- if (!m) {
- log_error("Could not allocate signal message.");
- goto finish;
+ r = bus_open_system_systemd(&bus);
+#else
+ /* Unlike in systemd where this has to use a private socket,
+ since elogind doesn't associate control groups with services
+ and doesn't manage the dbus service, we can just use the
+ system bus. */
+ r = sd_bus_open_system(&bus);
+#endif // 0
+
+ if (r < 0) {
+#if 0
+ /* If we couldn't connect we assume this was triggered
+ * while systemd got restarted/transitioned from
+ * initrd to the system, so let's ignore this */
+ log_debug_errno(r, "Failed to get D-Bus connection: %m");
+#else
+ /* If dbus isn't running or responding, there is nothing
+ * we can do about it. */
+ log_debug_errno(r, "Failed to open system bus: %m");
+#endif // 0
+ return EXIT_FAILURE;
}
- if (!dbus_message_append_args(m,
- DBUS_TYPE_STRING, &argv[1],
- DBUS_TYPE_INVALID)) {
- log_error("Could not attach group information to signal message.");
- goto finish;
+ r = sd_bus_emit_signal(bus,
+ "/org/freedesktop/elogind/agent",
+ "org.freedesktop.elogind.Agent",
+ "Released",
+ "s", argv[1]);
+ if (r < 0) {
+#if 0
+ log_debug_errno(r, "Failed to send signal message on private connection: %m");
+#else
+ log_debug_errno(r, "Failed to send signal message: %m");
+#endif // 0
+ return EXIT_FAILURE;
}
- if (!dbus_connection_send(bus, m, NULL)) {
- log_error("Failed to send signal message on private connection.");
- goto finish;
- }
-
- r = EXIT_SUCCESS;
-
-finish:
- if (bus) {
- dbus_connection_flush(bus);
- dbus_connection_close(bus);
- dbus_connection_unref(bus);
- }
-
- if (m)
- dbus_message_unref(m);
-
- dbus_error_free(&error);
- return r;
+ return EXIT_SUCCESS;
}