chiark / gitweb /
unit: add minimal condition checker for unit startup
[elogind.git] / src / unit.h
index e3c0c0f060d3960545c32e52fbb63baae45e6351..fa869ece8fb7859dbea2def6c055dd1b68632796 100644 (file)
@@ -38,8 +38,8 @@ typedef enum UnitDependency UnitDependency;
 #include "list.h"
 #include "socket-util.h"
 #include "execute.h"
+#include "condition.h"
 
-#define UNIT_NAME_MAX 256
 #define DEFAULT_TIMEOUT_USEC (60*USEC_PER_SEC)
 #define DEFAULT_RESTART_USEC (100*USEC_PER_MSEC)
 
@@ -61,8 +61,9 @@ enum UnitType {
 enum UnitLoadState {
         UNIT_STUB,
         UNIT_LOADED,
-        UNIT_FAILED,
+        UNIT_ERROR,
         UNIT_MERGED,
+        UNIT_MASKED,
         _UNIT_LOAD_STATE_MAX,
         _UNIT_LOAD_STATE_INVALID = -1
 };
@@ -71,7 +72,7 @@ enum UnitActiveState {
         UNIT_ACTIVE,
         UNIT_RELOADING,
         UNIT_INACTIVE,
-        UNIT_MAINTENANCE,
+        UNIT_FAILED,
         UNIT_ACTIVATING,
         UNIT_DEACTIVATING,
         _UNIT_ACTIVE_STATE_MAX,
@@ -87,11 +88,11 @@ static inline bool UNIT_IS_ACTIVE_OR_ACTIVATING(UnitActiveState t) {
 }
 
 static inline bool UNIT_IS_INACTIVE_OR_DEACTIVATING(UnitActiveState t) {
-        return t == UNIT_INACTIVE || t == UNIT_MAINTENANCE || t == UNIT_DEACTIVATING;
+        return t == UNIT_INACTIVE || t == UNIT_FAILED || t == UNIT_DEACTIVATING;
 }
 
-static inline bool UNIT_IS_INACTIVE_OR_MAINTENANCE(UnitActiveState t) {
-        return t == UNIT_INACTIVE || t == UNIT_MAINTENANCE;
+static inline bool UNIT_IS_INACTIVE_OR_FAILED(UnitActiveState t) {
+        return t == UNIT_INACTIVE || t == UNIT_FAILED;
 }
 
 enum UnitDependency {
@@ -154,6 +155,9 @@ struct Meta {
 
         usec_t job_timeout;
 
+        /* Conditions to check */
+        LIST_HEAD(Condition, conditions);
+
         dual_timestamp inactive_exit_timestamp;
         dual_timestamp active_enter_timestamp;
         dual_timestamp active_exit_timestamp;
@@ -304,8 +308,8 @@ struct UnitVTable {
         void (*sigchld_event)(Unit *u, pid_t pid, int code, int status);
         void (*timer_event)(Unit *u, uint64_t n_elapsed, Watch *w);
 
-        /* Reset maintenance state if we are in maintainance state */
-        void (*reset_maintenance)(Unit *u);
+        /* Reset failed state if we are in failed state */
+        void (*reset_failed)(Unit *u);
 
         /* Called whenever any of the cgroups this unit watches for
          * ran empty */
@@ -338,7 +342,7 @@ struct UnitVTable {
         void (*shutdown)(Manager *m);
 
         /* When sending out PropertiesChanged signal, which properties
-         * shall be invalidated? This is a NUL seperated list of
+         * shall be invalidated? This is a NUL separated list of
          * strings, to minimize relocations a little. */
         const char *bus_invalidating_properties;
 
@@ -495,10 +499,18 @@ void unit_status_printf(Unit *u, const char *format, ...);
 
 bool unit_need_daemon_reload(Unit *u);
 
-void unit_reset_maintenance(Unit *u);
+void unit_reset_failed(Unit *u);
 
 Unit *unit_following(Unit *u);
 
+bool unit_pending_inactive(Unit *u);
+bool unit_pending_active(Unit *u);
+
+int unit_add_default_target_dependency(Unit *u, Unit *target);
+
+UnitType unit_name_to_type(const char *n);
+bool unit_name_is_valid(const char *n, bool template_ok);
+
 const char *unit_load_state_to_string(UnitLoadState i);
 UnitLoadState unit_load_state_from_string(const char *s);