chiark / gitweb /
sd-rtnl: fix compile
[elogind.git] / man / busctl.xml
1 <?xml version='1.0'?> <!--*- Mode: nxml; nxml-child-indent: 2; indent-tabs-mode: nil -*-->
2 <!DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.2//EN"
3 "http://www.oasis-open.org/docbook/xml/4.2/docbookx.dtd">
4
5 <!--
6 This file is part of systemd.
7
8 Copyright 2014 Zbigniew Jędrzejewski-Szmek
9
10 systemd is free software; you can redistribute it and/or modify it
11 under the terms of the GNU Lesser General Public License as published by
12 the Free Software Foundation; either version 2.1 of the License, or
13 (at your option) any later version.
14
15 systemd is distributed in the hope that it will be useful, but
16 WITHOUT ANY WARRANTY; without even the implied warranty of
17 MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
18 Lesser General Public License for more details.
19
20 You should have received a copy of the GNU Lesser General Public License
21 along with systemd; If not, see <http://www.gnu.org/licenses/>.
22 -->
23
24 <refentry id="busctl"
25           xmlns:xi="http://www.w3.org/2001/XInclude">
26
27   <refentryinfo>
28     <title>busctl</title>
29     <productname>systemd</productname>
30
31     <authorgroup>
32       <author>
33         <contrib>A monkey with a typewriter</contrib>
34         <firstname>Zbigniew</firstname>
35         <surname>Jędrzejewski-Szmek</surname>
36         <email>zbyszek@in.waw.pl</email>
37       </author>
38     </authorgroup>
39   </refentryinfo>
40
41   <refmeta>
42     <refentrytitle>busctl</refentrytitle>
43     <manvolnum>1</manvolnum>
44   </refmeta>
45
46   <refnamediv>
47     <refname>busctl</refname>
48     <refpurpose>Introspect the bus</refpurpose>
49   </refnamediv>
50
51   <refsynopsisdiv>
52     <cmdsynopsis>
53       <command>busctl</command>
54       <arg choice="opt" rep="repeat">OPTIONS</arg>
55       <arg choice="opt">COMMAND</arg>
56       <arg choice="opt" rep="repeat"><replaceable>NAME</replaceable></arg>
57     </cmdsynopsis>
58   </refsynopsisdiv>
59
60   <refsect1>
61     <title>Description</title>
62
63     <para><command>busctl</command> may be used to
64     introspect and monitor the D-Bus bus.</para>
65   </refsect1>
66
67   <refsect1>
68     <title>Options</title>
69
70     <para>The following options are understood:</para>
71
72     <variablelist>
73       <varlistentry>
74           <term><option>--address=<replaceable>ADDRESS</replaceable></option></term>
75
76           <listitem><para>Connect to the bus specified by
77           <replaceable>ADDRESS</replaceable> instead of using suitable
78           defaults for either the system or user bus (see
79           <option>--system</option> and <option>--user</option>
80           options).</para></listitem>
81       </varlistentry>
82
83       <varlistentry>
84           <term><option>--show-machine</option></term>
85
86           <listitem><para>When showing the list of endpoints, show a
87           column containing the names of containers they belong to.
88           See
89           <citerefentry><refentrytitle>systemd-machined.service</refentrytitle><manvolnum>8</manvolnum></citerefentry>.
90           </para></listitem>
91       </varlistentry>
92
93       <varlistentry>
94           <term><option>--unique</option></term>
95
96           <listitem><para>When showing the list of endpoints, show
97           only "unique" names (of the form
98           <literal>:<replaceable>number</replaceable>.<replaceable>number</replaceable></literal>).
99           </para></listitem>
100       </varlistentry>
101
102       <varlistentry>
103           <term><option>--acquired</option></term>
104
105           <listitem><para>The opposite of <option>--unique</option> —
106           only "well-known" names will be shown.</para></listitem>
107       </varlistentry>
108
109       <varlistentry>
110           <term><option>--activatable</option></term>
111
112           <listitem><para>When showing the list of endpoints, show
113           only endpoints which have actually not been activated yet,
114           but may be started automatically if accessed.</para>
115           </listitem>
116       </varlistentry>
117
118       <varlistentry>
119           <term><option>--match=<replaceable>MATCH</replaceable></option></term>
120
121           <listitem><para>When showing messages being exchanged, show only the
122           subset matching <replaceable>MATCH</replaceable>.</para></listitem>
123           <!-- TODO: link to sd_bus_add_match when it is written? -->
124       </varlistentry>
125
126       <varlistentry>
127         <term><option>--no-legend</option></term>
128
129         <listitem>
130           <para>Do not print the legend,
131           i.e. the column headers and the
132           footer.</para>
133         </listitem>
134       </varlistentry>
135
136       <varlistentry>
137         <term><option>--size=</option></term>
138
139         <listitem>
140           <para>When used with the <command>capture</command> command
141           specifies the maximum bus message size to capture
142           ("snaplen"). Defaults to 4096 bytes.</para>
143         </listitem>
144       </varlistentry>
145
146       <varlistentry>
147         <term><option>--list</option></term>
148
149         <listitem>
150           <para>When used with the <command>tree</command> command shows a
151           flat list of object paths instead of a tree.</para>
152         </listitem>
153       </varlistentry>
154
155       <varlistentry>
156         <term><option>--quiet</option></term>
157
158         <listitem>
159           <para>When used with the <command>call</command> command
160           suppresses display of the response message payload. Note that even
161           if this option is specified errors returned will still be
162           printed and the tool will indicate success or failure with
163           the process exit code.</para>
164         </listitem>
165       </varlistentry>
166
167       <varlistentry>
168         <term><option>--verbose</option></term>
169
170         <listitem>
171           <para>When used with the <command>call</command> or
172           <command>get-property</command> command shows output in a
173           more verbose format.</para>
174         </listitem>
175       </varlistentry>
176
177       <varlistentry>
178         <term><option>--expect-reply=</option><replaceable>BOOL</replaceable></term>
179
180         <listitem>
181           <para>When used with the <command>call</command> command
182           specifies whether <command>busctl</command> shall wait for
183           completion of the method call, output the returned method
184           response data, and return success or failure via the process
185           exit code. If this is set to <literal>no</literal> the
186           method call will be issued but no response is expected, the
187           tool terminates immediately, and thus no response can be
188           shown, and no success or failure is returned via the exit
189           code. To only suppress output of the reply message payload
190           use <option>--quiet</option> above. Defaults to
191           <literal>yes</literal>.</para>
192         </listitem>
193       </varlistentry>
194
195       <varlistentry>
196         <term><option>--auto-start=</option><replaceable>BOOL</replaceable></term>
197
198         <listitem>
199           <para>When used with the <command>call</command> command specifies
200           whether the method call should implicitly activate the
201           called service should it not be running yet but is
202           configured to be auto-started. Defaults to
203           <literal>yes</literal>.</para>
204         </listitem>
205       </varlistentry>
206
207       <varlistentry>
208         <term><option>--allow-interactive-authorization=</option><replaceable>BOOL</replaceable></term>
209
210         <listitem>
211           <para>When used with the <command>call</command> command
212           specifies whether the services may enforce interactive
213           authorization while executing the operation, if the security
214           policy is configured for this. Defaults to
215           <literal>yes</literal>.</para>
216         </listitem>
217       </varlistentry>
218
219       <varlistentry>
220         <term><option>--timeout=</option><replaceable>SECS</replaceable></term>
221
222         <listitem>
223           <para>When used with the <command>call</command> command
224           specifies the maximum time to wait for method call
225           completion. If no time unit is specified assumes
226           seconds. The usual other units are understood, too (ms, us,
227           s, min, h, d, w, month, y). Note that this timeout does not
228           apply if <option>--expect-reply=no</option> is used as the
229           tool does not wait for any reply message then. When not
230           specified or when set to 0 the default of
231           <literal>25s</literal> is assumed.</para>
232         </listitem>
233       </varlistentry>
234
235       <varlistentry>
236         <term><option>--augment-creds=</option><replaceable>BOOL</replaceable></term>
237
238         <listitem>
239           <para>Controls whether credential data reported by
240           <command>list</command> or <command>status</command> shall
241           be augmented with data from
242           <filename>/proc</filename>. When this is turned on the data
243           shown is possibly inconsistent, as the data read from
244           <filename>/proc</filename> might be more recent than rest of
245           the credential information. Defaults to <literal>yes</literal>.</para>
246         </listitem>
247       </varlistentry>
248
249       <xi:include href="user-system-options.xml" xpointer="user" />
250       <xi:include href="user-system-options.xml" xpointer="system" />
251       <xi:include href="user-system-options.xml" xpointer="host" />
252       <xi:include href="user-system-options.xml" xpointer="machine" />
253
254       <xi:include href="standard-options.xml" xpointer="help" />
255       <xi:include href="standard-options.xml" xpointer="version" />
256       <xi:include href="standard-options.xml" xpointer="no-pager" />
257     </variablelist>
258   </refsect1>
259
260   <refsect1>
261     <title>Commands</title>
262
263     <para>The following commands are understood:</para>
264
265     <variablelist>
266       <varlistentry>
267         <term><command>list</command></term>
268
269         <listitem><para>Show service names on the bus. This is the
270         default if no command is specified.</para></listitem>
271       </varlistentry>
272
273       <varlistentry>
274         <term><command>status</command> <arg choice="opt"><replaceable>SERVICE</replaceable></arg></term>
275
276         <listitem><para>Show process information and credentials of a
277         bus service (if one is specified by its unique or well-known
278         name), a process (if one is specified by its numeric PID), or
279         the owner of the bus (if no parameter is
280         specified).</para></listitem>
281       </varlistentry>
282
283       <varlistentry>
284         <term><command>monitor</command> <arg choice="opt" rep="repeat"><replaceable>SERVICE</replaceable></arg></term>
285
286         <listitem><para>Dump messages being exchanged. If
287         <replaceable>SERVICE</replaceable> is specified, show messages
288         to or from this endpoint. Otherwise, show all messages on the
289         bus. Use Ctrl-C to terminate dump.</para></listitem>
290       </varlistentry>
291
292       <varlistentry>
293         <term><command>capture</command> <arg choice="opt" rep="repeat"><replaceable>SERVICE</replaceable></arg></term>
294
295         <listitem><para>Similar to <command>monitor</command> but
296         writes the output in pcap format (for details see the <ulink
297         url="http://wiki.wireshark.org/Development/LibpcapFileFormat">Libpcap
298         File Format</ulink> description. Make sure to redirect the
299         output to STDOUT to a file. Tools like
300         <citerefentry><refentrytitle>wireshark</refentrytitle><manvolnum>1</manvolnum></citerefentry>
301         may be used to dissect and view the generated
302         files.</para></listitem>
303       </varlistentry>
304
305       <varlistentry>
306         <term><command>tree</command> <arg choice="opt" rep="repeat"><replaceable>SERVICE</replaceable></arg></term>
307
308         <listitem><para>Shows an object tree of one or more
309         services. If <replaceable>SERVICE</replaceable> is specified,
310         show object tree of the specified services only. Otherwise,
311         show all object trees of all services on the bus that acquired
312         at least one well-known name.</para></listitem>
313       </varlistentry>
314
315       <varlistentry>
316         <term><command>introspect</command> <arg choice="plain"><replaceable>SERVICE</replaceable></arg> <arg choice="plain"><replaceable>OBJECT</replaceable></arg></term>
317
318         <listitem><para>Show interfaces, methods, properties and
319         signals of the specified object (identified by its path) on
320         the specified service.</para></listitem>
321       </varlistentry>
322
323       <varlistentry>
324         <term><command>call</command> <arg choice="plain"><replaceable>SERVICE</replaceable></arg> <arg choice="plain"><replaceable>OBJECT</replaceable></arg> <arg choice="plain"><replaceable>INTERFACE</replaceable></arg> <arg choice="plain"><replaceable>METHOD</replaceable></arg> <arg choice="opt"><replaceable>SIGNATURE</replaceable> <arg choice="opt" rep="repeat"><replaceable>ARGUMENT</replaceable></arg></arg></term>
325
326         <listitem><para>Invoke a method and show the response. Takes a
327         service name, object path, interface name and method name. If
328         parameters shall be passed to the method call a signature
329         string is required, followed by the arguments, individually
330         formatted as strings. For details on the formatting used, see
331         below. To suppress output of the returned data use the
332         <option>--quiet</option> option.</para></listitem>
333       </varlistentry>
334
335       <varlistentry>
336         <term><command>get-property</command> <arg choice="plain"><replaceable>SERVICE</replaceable></arg> <arg choice="plain"><replaceable>OBJECT</replaceable></arg> <arg choice="plain"><replaceable>INTERFACE</replaceable></arg> <arg choice="plain" rep="repeat"><replaceable>PROPERTY</replaceable></arg></term>
337
338         <listitem><para>Retrieve the current value of one or more
339         object properties. Takes a service name, object path,
340         interface name and property name. Multiple properties may be
341         specified at once in which case their values will be shown one
342         after the other, separated by newlines. The output is by
343         default in terse format. Use <option>--verbose</option> for a
344         more elaborate output format.</para></listitem>
345       </varlistentry>
346
347       <varlistentry>
348         <term><command>set-property</command> <arg choice="plain"><replaceable>SERVICE</replaceable></arg> <arg choice="plain"><replaceable>OBJECT</replaceable></arg> <arg choice="plain"><replaceable>INTERFACE</replaceable></arg> <arg choice="plain"><replaceable>PROPERTY</replaceable></arg> <arg choice="plain"><replaceable>SIGNATURE</replaceable></arg> <arg choice="plain" rep="repeat"><replaceable>ARGUMENT</replaceable></arg></term>
349
350         <listitem><para>Set the current value an object
351         property. Takes a service name, object path, interface name,
352         property name, property signature, followed by a list of
353         parameters formatted as strings.</para></listitem>
354       </varlistentry>
355
356       <varlistentry>
357         <term><command>help</command></term>
358
359         <listitem><para>Show command syntax help.</para></listitem>
360       </varlistentry>
361     </variablelist>
362   </refsect1>
363
364   <refsect1>
365     <title>Parameter Formatting</title>
366
367     <para>The <command>call</command> and
368     <command>set-property</command> commands take a signature string
369     followed by a list of parameters formatted as string (for details
370     on D-Bus signature strings see the <ulink
371     url="http://dbus.freedesktop.org/doc/dbus-specification.html#type-system">Type
372     system chapter of the D-Bus specification</ulink>). For simple
373     types each parameter following the signature should simply be the
374     parameter's value formatted as string. Positive boolean values may
375     be formatted as <literal>true</literal>, <literal>yes</literal>,
376     <literal>on</literal>, <literal>1</literal>; negative boolean
377     values may be specified as <literal>false</literal>,
378     <literal>no</literal>, <literal>off</literal>,
379     <literal>0</literal>. For arrays, a numeric argument for the
380     number of entries followed by the entries shall be specified. For
381     variants the signature of the contents shall be specified,
382     followed by the contents. For dictionaries and structs the
383     contents of them shall be directly specified.</para>
384
385     <para>For example,
386     <programlisting>s jawoll</programlisting> is the formatting
387     of a single string <literal>jawoll</literal>.</para>
388
389     <para>
390     <programlisting>as 3 hello world foobar</programlisting>
391     is the formatting of a string array with three entries,
392     <literal>hello</literal>, <literal>world</literal> and
393     <literal>foobar</literal>.</para>
394
395     <para>
396     <programlisting>a{sv} 3 One s Eins Two u 2 Yes b true</programlisting>
397     is the formatting of a dictionary
398     array that maps strings to variants, consisting of three
399     entries. The string <literal>One</literal> is assigned the
400     string <literal>Eins</literal>. The string
401     <literal>Two</literal> is assigned the 32bit unsigned
402     integer 2. The string <literal>Yes</literal> is assigned a
403     positive boolean.</para>
404
405     <para>Note that the <command>call</command>,
406     <command>get-property</command>, <command>introspect</command>
407     commands will also generate output in this format for the returned
408     data. Since this format is sometimes too terse to be easily
409     understood, the <command>call</command> and
410     <command>get-property</command> commands may generate a more
411     verbose, multi-line output when passed the
412     <option>--verbose</option> option.</para>
413   </refsect1>
414
415   <refsect1>
416     <title>Examples</title>
417
418     <example>
419       <title>Write and Read a Property</title>
420
421       <para>The following two commands first write a property and then
422       read it back. The property is found on the
423       <literal>/org/freedesktop/systemd1</literal> object of the
424       <literal>org.freedesktop.systemd1</literal> service. The name of
425       the property is <literal>LogLevel</literal> on the
426       <literal>org.freedesktop.systemd1.Manager</literal>
427       interface. The property contains a single string:</para>
428
429       <programlisting># busctl set-property org.freedesktop.systemd1 /org/freedesktop/systemd1 org.freedesktop.systemd1.Manager LogLevel s debug
430 # busctl get-property org.freedesktop.systemd1 /org/freedesktop/systemd1 org.freedesktop.systemd1.Manager LogLevel
431 s "debug"</programlisting>
432
433     </example>
434
435     <example>
436       <title>Terse and Verbose Output</title>
437
438       <para>The following two commands read a property that contains
439       an array of strings, and first show it in terse format, followed
440       by verbose format:</para>
441
442       <programlisting>$ busctl get-property org.freedesktop.systemd1 /org/freedesktop/systemd1 org.freedesktop.systemd1.Manager Environment
443 as 2 "LANG=en_US.UTF-8" "PATH=/usr/local/sbin:/usr/local/bin:/usr/sbin:/usr/bin"
444 $ busctl get-property --verbose org.freedesktop.systemd1 /org/freedesktop/systemd1 org.freedesktop.systemd1.Manager Environment
445 ARRAY "s" {
446         STRING "LANG=en_US.UTF-8";
447         STRING "PATH=/usr/local/sbin:/usr/local/bin:/usr/sbin:/usr/bin";
448 };</programlisting>
449     </example>
450
451     <example>
452       <title>Invoking a Method</title>
453
454       <para>The following command invokes a the
455       <literal>StartUnit</literal> method on the
456       <literal>org.freedesktop.systemd1.Manager</literal>
457       interface of the
458       <literal>/org/freedesktop/systemd1</literal> object
459       of the <literal>org.freedesktop.systemd1</literal>
460       service, and passes it two strings
461       <literal>cups.service</literal> and
462       <literal>replace</literal>. As result of the method
463       call a single object path parameter is received and
464       shown:</para>
465
466       <programlisting># busctl call org.freedesktop.systemd1 /org/freedesktop/systemd1 org.freedesktop.systemd1.Manager StartUnit ss "cups.service" "replace"
467 o "/org/freedesktop/systemd1/job/42684"</programlisting>
468     </example>
469   </refsect1>
470
471   <refsect1>
472     <title>See Also</title>
473
474     <para>
475       <citerefentry><refentrytitle>dbus-daemon</refentrytitle><manvolnum>1</manvolnum></citerefentry>,
476       <ulink url="http://freedesktop.org/wiki/Software/dbus">D-Bus</ulink>,
477       <ulink url="https://code.google.com/p/d-bus/">kdbus</ulink>,
478       <citerefentry><refentrytitle>sd-bus</refentrytitle><manvolnum>3</manvolnum></citerefentry>,
479       <citerefentry><refentrytitle>systemd</refentrytitle><manvolnum>1</manvolnum></citerefentry>,
480       <citerefentry><refentrytitle>systemd-bus-proxyd</refentrytitle><manvolnum>8</manvolnum></citerefentry>,
481       <citerefentry><refentrytitle>machinectl</refentrytitle><manvolnum>1</manvolnum></citerefentry>,
482       <citerefentry><refentrytitle>wireshark</refentrytitle><manvolnum>1</manvolnum></citerefentry>
483     </para>
484   </refsect1>
485 </refentry>