chiark / gitweb /
main: fix auto restarting of units after a configuration reload
[elogind.git] / src / dbus-manager.c
index 63e80838059be507fccceb3e2e1cb4f3bc7d5845..549f175eb940e321114633767fee270ee9a45078 100644 (file)
         "  <property name=\"Environment\" type=\"as\" access=\"read\"/>\n" \
         "  <property name=\"ConfirmSpawn\" type=\"b\" access=\"read\"/>\n" \
         "  <property name=\"ShowStatus\" type=\"b\" access=\"read\"/>\n" \
+        "  <property name=\"SysVConsole\" type=\"b\" access=\"read\"/>\n" \
         "  <property name=\"UnitPath\" type=\"as\" access=\"read\"/>\n" \
         "  <property name=\"SysVInitPath\" type=\"as\" access=\"read\"/>\n" \
         "  <property name=\"SysVRcndPath\" type=\"as\" access=\"read\"/>\n" \
@@ -240,6 +241,7 @@ static DBusHandlerResult bus_manager_message_handler(DBusConnection *connection,
                 { "org.freedesktop.systemd1.Manager", "Environment",   bus_property_append_strv,      "as", m->environment     },
                 { "org.freedesktop.systemd1.Manager", "ConfirmSpawn",  bus_property_append_bool,      "b",  &m->confirm_spawn  },
                 { "org.freedesktop.systemd1.Manager", "ShowStatus",    bus_property_append_bool,      "b",  &m->show_status    },
+                { "org.freedesktop.systemd1.Manager", "SysVConsole",   bus_property_append_bool,      "b",  &m->sysv_console   },
                 { "org.freedesktop.systemd1.Manager", "UnitPath",      bus_property_append_strv,      "as", m->lookup_paths.unit_path },
                 { "org.freedesktop.systemd1.Manager", "SysVInitPath",  bus_property_append_strv,      "as", m->lookup_paths.sysvinit_path },
                 { "org.freedesktop.systemd1.Manager", "SysVRcndPath",  bus_property_append_strv,      "as", m->lookup_paths.sysvrcnd_path },
@@ -413,6 +415,7 @@ static DBusHandlerResult bus_manager_message_handler(DBusConnection *connection,
                         const char *description, *load_state, *active_state, *sub_state, *sjob_type, *following;
                         DBusMessageIter sub2;
                         uint32_t job_id;
+                        Unit *f;
 
                         if (k != u->meta.id)
                                 continue;
@@ -424,7 +427,9 @@ static DBusHandlerResult bus_manager_message_handler(DBusConnection *connection,
                         load_state = unit_load_state_to_string(u->meta.load_state);
                         active_state = unit_active_state_to_string(unit_active_state(u));
                         sub_state = unit_sub_state_to_string(u);
-                        following = u->meta.following ? u->meta.following->meta.id : "";
+
+                        f = unit_following(u);
+                        following = f ? f->meta.id : "";
 
                         if (!(u_path = unit_dbus_path(u)))
                                 goto oom;