chiark / gitweb /
systemctl: implement 'status' command
[elogind.git] / man / systemd.exec.xml
index 83eef32f55531f19a07d8378cc505147f5b9a789..6502d87b4ad48d29d2750c1e8cfe4a0e3bbff660 100644 (file)
                                 the default log level specified
                                 here. The interpretation of these
                                 prefixes may be disabled with
                                 the default log level specified
                                 here. The interpretation of these
                                 prefixes may be disabled with
-                                <varname>SyslogNoPrefix=</varname>,
+                                <varname>SyslogLevelPrefix=</varname>,
                                 see below. For details see
                                 <citerefentry><refentrytitle>sd-daemon</refentrytitle><manvolnum>7</manvolnum></citerefentry>.
 
                                 see below. For details see
                                 <citerefentry><refentrytitle>sd-daemon</refentrytitle><manvolnum>7</manvolnum></citerefentry>.
 
                         </varlistentry>
 
                         <varlistentry>
                         </varlistentry>
 
                         <varlistentry>
-                                <term><varname>SyslogNoPrefix=</varname></term>
+                                <term><varname>SyslogLevelPrefix=</varname></term>
                                 <listitem><para>Takes a boolean
                                 <listitem><para>Takes a boolean
-                                argument. If false and
+                                argument. If true and
                                 <varname>StandardOutput=</varname> or
                                 <varname>StandardError=</varname> are
                                 set to <option>syslog</option> or
                                 <varname>StandardOutput=</varname> or
                                 <varname>StandardError=</varname> are
                                 set to <option>syslog</option> or
                                 are prefixed with a log level will be
                                 passed on to syslog with this log
                                 level set but the prefix removed. If
                                 are prefixed with a log level will be
                                 passed on to syslog with this log
                                 level set but the prefix removed. If
-                                set to true, the interpretation of
+                                set to false, the interpretation of
                                 these prefixes is disabled and the
                                 logged lines are passed on as-is. For
                                 details about this prefixing see
                                 <citerefentry><refentrytitle>sd-daemon</refentrytitle><manvolnum>7</manvolnum></citerefentry>.
                                 these prefixes is disabled and the
                                 logged lines are passed on as-is. For
                                 details about this prefixing see
                                 <citerefentry><refentrytitle>sd-daemon</refentrytitle><manvolnum>7</manvolnum></citerefentry>.
-                                Defaults to false.</para></listitem>
+                                Defaults to true.</para></listitem>
                         </varlistentry>
 
                         <varlistentry>
                         </varlistentry>
 
                         <varlistentry>