be logged and a nonzero exit.
.TP
.BR \-\-no-daemon
+Do not daemonise. innduct runs in the foreground, but otherwise
+operates normally (logging to syslog, etc.).
+.TP
+.BR \-\-interactive
Do not daemonise. innduct runs in the foreground and all messages
(including all debug messages) are written to stderr rather than
syslog. A control command line is also available on stdin/stdout.
.IR PERIOD )
are rounded up to the next multiple of
.IR PERIOD-INTERVAL .
+The default is
+.BR 30s .
.TP
.BI \-\-connection-timeout= TIME
How long to allow for a connection setup attempt before giving up.
The default is
.BR 1000s .
.TP
+.BI \-\-low-volume-thresh= "WIN-THRESH " \-\-low-volume-window= "PERIOD "
+If innduct has only one connection to the peer, and has processed
+fewer than
+.I WIN-THRESH
+articles in the last
+.I PERIOD
+and also no articles in the last
+.IR PERIOD-INTERVAL
+it will close the connection quickly. That is, innduct switches to a
+mode where it opens a connection for each article (or, perhaps, each
+handful of articles arriving together).
+The default is to close if fewer than
+.BR 3
+articles in the last
+.BR 1000s .
+.TP
.BI \-\-max-bad-input-data-ratio= PERCENT
We tolerate up to this proportion of badly-formatted lines in the
feedfile and other input files. Every badly-formatted line is logged,